January 9, 2023
INCREASE IN PUMP TEMPERATURE – CASE STUDY
EVENT REPORTED by SAM GUARD®
Detected a continuing trend of an ongoing increase in pump temperature from 20 °C to 50 °C. The main concern is a failure of the acrylic acid pump, which stops production.
MAINTENANCE TEAM FINDINGS
Following the SAMGUARD® alert, the plant found that the temperature indicator measures the wrong temperature, and instead of measuring the pump temperature it measures the ambient temperature inside a water bottle.
COST / DOWNTIME AVOIDED
Early detection helped identify abnormal measurements and to prevent future failures in the process.
CUSTOMER FEEDBACK
“Important detection by SAM GUARD®.After the event, the plant team noticed that the temperature indicator measures the wrong temperature and instead of measuring the pump temperature it measures the ambient temperature inside a water bottle “